FläktWoods Documentation

Note: The documentation always refers to the latest version of the plugin

Plugin Connectors

Connector Type Description
 Setpoint input, string  Sets the desired temperature
 Mode: Off input, trigger  This predefined mode turns of the ventilation
 Mode: Timer input, trigger  This mode uses a predefined timer setting
 Mode: Normal input, trigger  This mode is for normal usage
 Mode: Fireplace input, trigger  This mode creates a over pressure making it easier to start a fire
 Supply Fan, Trickle speed input, string  Sets the supply fan speed (%) for Trickle mode. Note: This value is stored in the HVAC device for this mode!
 Supply Fan, Normal speed input, string  Sets the supply fan speed (%) for Normal mode. Note: This value is stored in the HVAC device for this mode!
 Supply Fan, Boost speed input, string  Sets the supply fan speed (%) for Boost mode. Note: This value is stored in the HVAC device for this mode!
 Supply Fan, Coocker hood speed input, string  Sets the supply fan speed (%) for Coocker hood mode. Note: This value is stored in the HVAC device for this mode!
 Extract Fan, Trickle speed input, string  Sets the extract fan speed (%) for Trickle mode. Note: This value is stored in the HVAC device for this mode!
 Extract Fan, Normal speed input, string  Sets the extract fan speed (%) for Normal mode. Note: This value is stored in the HVAC device for this mode!
 Extract Fan, Boost speed input, string  Sets the extract fan speed (%) for Boost mode. Note: This value is stored in the HVAC device for this mode!
 Extract Fan, Coocker hood speed input, string  Sets the extract fan speed (%) for Coocker hood mode. Note: This value is stored in the HVAC device for this mode!
 Outdoor Temperature ouput, string  Outdoor Temperature
 CO2 ouput, string  CO2 measured in ppm. This output requires a special module in the ventilation system.
 Supply Temperature ouput, string  Supply air temperature
 Supply fan speed ouput, string  Fan speed measured in %
 Extract Temperature (room) ouput, string  This is the measured room temperatures
 Extract fan speed ouput, string  Fan speed measured in %
 Post heater defrost ouput, string
 Post heating ouput, string  Post heating measured in %
 Pre heater defrost ouput, string
 Pre heating ouput, string  Pre heating measured in %
 PHE/RHE defrost ouput, string
 Humidity Parameter 1 ouput, string  Humidity measured in %rH
 Humidity Parameter 2 ouput, string  Humidity measured in %rH
 Cooling ouput, string  Cooling measured in %
 Heating/Cooling Recovery ouput, string  Recovery measured in %
 Ventilation Error ouput, string  Errors reported by the ventilation system

Plugin Settings

Setting Valuetype Description
IP nn.nn.nn.nn IP adress to the FläktWoods system
PollingDelay n Delay, in milliseconds, between each check for updated data against the FläktWoods system